Fuel tank calibration - measured

Post Reply
User avatar
meridian
First Mate
First Mate
Posts: 112
Joined: Wed Sep 21, 2011 9:00 pm
Home Port: Looper

Fuel tank calibration - measured

Post by meridian »

has anyone calibrated their 36-DC fuel tanks. If so, do you have the measurements? ie site tube showing 14" from bottom of tank equals x gallons left. I know the tanks are irregular in shape.
Last edited by meridian on Sun Sep 16, 2012 9:21 pm, edited 1 time in total.
-------------------------------
Terry
psneeld
Gold Member
Gold Member
Posts: 102
Joined: Sat Apr 04, 2009 8:13 am
Home Port: Avalon, NJ

Re: Fuel tank calibration

Post by psneeld »

it's pretty simple math if you have the dimensions of the tank...the hardest part to measure is the triangular section at the bottom of the tank.
Scott Neeld
Albin 40 Trawler
jleonard
Gold Member
Gold Member
Posts: 2115
Joined: Fri Sep 22, 2006 7:35 am
Home Port: Mystic, CT
Location: New Port Richey, FL

Re: Fuel tank calibration

Post by jleonard »

And even if you can't measure "exactly" who really cares? It will be close enough for practical purposes.
I have twin tanks and I can use a "calibrated dowel" on one of the tanks. 1/4,1/2,3/4,full are the only marks I need. Then I figure that percent of the 360 total capacity.
I can "guestimate" the amount left, or the amount I can take on within 10% which is more than close enough for cruising.
By the way my stick always agrees with the float type gage that I have on one tank.
Formerly
1983 40 Albin trunk cabin
Attitude Adjustment
Mystic, CT
User avatar
meridian
First Mate
First Mate
Posts: 112
Joined: Wed Sep 21, 2011 9:00 pm
Home Port: Looper

Re: Fuel tank calibration - measured

Post by meridian »

So I got the measurements for the tanks and did the following calculations. I used 4" increments although you could use any you want. The tank is 60" wide, 36" deep, and 24" tall in the front and 12" in the back from the top of the tank then slanted to reach the bottom of the tank in front. All numbers are approximate but the calculations come out close to 150 gallons.

Starting from the top of the tank

in/gal used/gal remaining
24 0 150
20 33 116
16 66 83
12 99 50
8 127 22
4 143 6
0 bottom 150 0

I'll put the numbers on a plastic strip and post it next to the sight glass. Remenber, this is just one tank, be sure to multilpy by two.


Please let me know if my calcs are off. I had to dig out my high school trig.
-------------------------------
Terry
User avatar
DougSea
Gold Member
Gold Member
Posts: 2762
Joined: Tue Jun 13, 2006 9:45 am
Home Port: Safe Harbor - Essex Island Marina, Essex, CT
Location: Essex, Connecticut

Re: Fuel tank calibration - measured

Post by DougSea »

Hi Terry,

So I was sitting in my hotel room and decided to engage my brain a bit. I broke the problem in half. Effectively you have a retangular tank measuring 36x60x12 sitting on top of a right triangular tank also measuring 60x36x12.

First came the easy math. The "upper" tank holds 25,920 cu in, or 112.208 gallons. The "lower" tank holds half of that, 12,960 cu in, or 56.104 gallons.

I broke out my Google-fu and found a right triangle area calculator, used the big triangle (12x36) to figure out one of the other angles (18.4 degrees and 71.6 degrees if you're interested) and then figured out the areas of my decreasingly sized triangles.

My results, expressed as the total remaining, are:

24" - 168.313
20" - 130.910
16" - 93.507
12" - 56.104
8" - 24.987
4" - 6.234

All in US gallons.

The areas I got for the lower triangles were 216, 96.2, and 24 sq inches respectively.
Doug
Sonny IV
2006 35TE Convertible, Volvo D6-370's
Former owner - Sonny III, 1997 28TE with "The BEAST"
User avatar
DougSea
Gold Member
Gold Member
Posts: 2762
Joined: Tue Jun 13, 2006 9:45 am
Home Port: Safe Harbor - Essex Island Marina, Essex, CT
Location: Essex, Connecticut

Re: Fuel tank calibration - measured

Post by DougSea »

Here's my "worksheet"

:-)
Tank Calculations.jpeg
You do not have the required permissions to view the files attached to this post. To view images, please register for a free account.
Doug
Sonny IV
2006 35TE Convertible, Volvo D6-370's
Former owner - Sonny III, 1997 28TE with "The BEAST"
User avatar
RobS
Gold Member
Gold Member
Posts: 4044
Joined: Wed Oct 03, 2007 6:20 am
Home Port: Center Moriches, NY
Contact:

Re: Fuel tank calibration - measured

Post by RobS »

So Terry's number have a little cushion. Doug: What, no bar at the hotel?
Rob S.
"TENACIOUS"
1974 Chris Craft 36' Commander Tournament
Cummins 6BTA 330B's

(Former Owner)
"TOY-RIFIC" 2000 28TE, 6LP, Hull 408

Luck is the residue of good design.
User avatar
DougSea
Gold Member
Gold Member
Posts: 2762
Joined: Tue Jun 13, 2006 9:45 am
Home Port: Safe Harbor - Essex Island Marina, Essex, CT
Location: Essex, Connecticut

Re: Fuel tank calibration - measured

Post by DougSea »

RobS wrote:So Terry's number have a little cushion. Doug: What, no bar at the hotel?
Yup! And it's good (with fuel) to know you erred on the conservative side! (Of course this means you then trust MY numbers as well...)

And of course there's a bar :) ...but if I spent all of my free time there it would be a problem. I'm already over 120 nights this year... :shock:
Doug
Sonny IV
2006 35TE Convertible, Volvo D6-370's
Former owner - Sonny III, 1997 28TE with "The BEAST"
User avatar
RobS
Gold Member
Gold Member
Posts: 4044
Joined: Wed Oct 03, 2007 6:20 am
Home Port: Center Moriches, NY
Contact:

Re: Fuel tank calibration - measured

Post by RobS »

Ouch, you spend more on hotel rooms and diesel fuel than most people make in a year!
Rob S.
"TENACIOUS"
1974 Chris Craft 36' Commander Tournament
Cummins 6BTA 330B's

(Former Owner)
"TOY-RIFIC" 2000 28TE, 6LP, Hull 408

Luck is the residue of good design.
User avatar
meridian
First Mate
First Mate
Posts: 112
Joined: Wed Sep 21, 2011 9:00 pm
Home Port: Looper

Re: Fuel tank calibration - measured

Post by meridian »

don't forget the thickness of the tank walls
-------------------------------
Terry
User avatar
DougSea
Gold Member
Gold Member
Posts: 2762
Joined: Tue Jun 13, 2006 9:45 am
Home Port: Safe Harbor - Essex Island Marina, Essex, CT
Location: Essex, Connecticut

Re: Fuel tank calibration - measured

Post by DougSea »

meridian wrote:don't forget the thickness of the tank walls
You mean you didn't give me the interior dimensions?? Next you'll tell me the corners are radiused!
Doug
Sonny IV
2006 35TE Convertible, Volvo D6-370's
Former owner - Sonny III, 1997 28TE with "The BEAST"
jleonard
Gold Member
Gold Member
Posts: 2115
Joined: Fri Sep 22, 2006 7:35 am
Home Port: Mystic, CT
Location: New Port Richey, FL

Re: Fuel tank calibration - measured

Post by jleonard »

Doug, did you subtract the volume of the pick up tubes, and add the volume of the sight tubes?
Barometric pressure? Temperature?
Formerly
1983 40 Albin trunk cabin
Attitude Adjustment
Mystic, CT
User avatar
DougSea
Gold Member
Gold Member
Posts: 2762
Joined: Tue Jun 13, 2006 9:45 am
Home Port: Safe Harbor - Essex Island Marina, Essex, CT
Location: Essex, Connecticut

Re: Fuel tank calibration - measured

Post by DougSea »

jleonard wrote:Doug, did you subtract the volume of the pick up tubes, and add the volume of the sight tubes?
Barometric pressure? Temperature?
Crap! More math!!

:lol:
Doug
Sonny IV
2006 35TE Convertible, Volvo D6-370's
Former owner - Sonny III, 1997 28TE with "The BEAST"
User avatar
RobS
Gold Member
Gold Member
Posts: 4044
Joined: Wed Oct 03, 2007 6:20 am
Home Port: Center Moriches, NY
Contact:

Re: Fuel tank calibration - measured

Post by RobS »

Next time just go to the hotel bar...
Rob S.
"TENACIOUS"
1974 Chris Craft 36' Commander Tournament
Cummins 6BTA 330B's

(Former Owner)
"TOY-RIFIC" 2000 28TE, 6LP, Hull 408

Luck is the residue of good design.
User avatar
meridian
First Mate
First Mate
Posts: 112
Joined: Wed Sep 21, 2011 9:00 pm
Home Port: Looper

Re: Fuel tank calibration - measured

Post by meridian »

you're makin my head hurt!
-------------------------------
Terry