• Welcome to https://albinowners.net, the new home of Albin Owners Group!
• You will need to log in here, and you may want to bookmark this site. If you don't remember your password, use the I forgot my password link to reset it.
• All content has been transferred from our previous site.
• Contact Us if you have any questions or notice a problem. If you're not receiving our email, include a phone number where we can text you.
• You will need to log in here, and you may want to bookmark this site. If you don't remember your password, use the I forgot my password link to reset it.
• All content has been transferred from our previous site.
• Contact Us if you have any questions or notice a problem. If you're not receiving our email, include a phone number where we can text you.
FAQ:
• Membership information
• Burgees
• How to post photos
• Membership information
• Burgees
• How to post photos
Generator installation
Generator installation
Good Evening: I am trying to re-install a Westerbeke generator and am not sure where to put it. We have a 1979 36ft aft-cabin. She had a generator originally but I'm not sure where. She appears to have all the plumbing. Does anyone have a diagram or photo of their installation? Do you think a 5.5kw is large enough? Thanks for all your help.
- DougSea
- Gold Member
- Posts: 2762
- Joined: Tue Jun 13, 2006 9:45 am
- Home Port: Safe Harbor - Essex Island Marina, Essex, CT
- Location: Essex, Connecticut
Re: Gernerator installation
Hey Jazzman,
I'd think a generator's original install location would be fairly easy to spot. It would need fittings for fuel, electrical connections (120/240v), battery, raw water and exhaust. Find them and trace them and you should find the spot!
As for size, that would depend on your loads. We have a 6kw and can run 2 A/C units, water heater, refrigerator, battery charger AND the stove! My circuits aren't balanced very well, too many big loads on one side of the 240v pannel, so sometimes one if the branch mains cuts out, but the generator breaker has never gone. You can always turn circuits off if you have too much going for it to handle.
I'd think a generator's original install location would be fairly easy to spot. It would need fittings for fuel, electrical connections (120/240v), battery, raw water and exhaust. Find them and trace them and you should find the spot!
As for size, that would depend on your loads. We have a 6kw and can run 2 A/C units, water heater, refrigerator, battery charger AND the stove! My circuits aren't balanced very well, too many big loads on one side of the 240v pannel, so sometimes one if the branch mains cuts out, but the generator breaker has never gone. You can always turn circuits off if you have too much going for it to handle.
Doug
Sonny IV
2006 35TE Convertible, Volvo D6-370's
Former owner - Sonny III, 1997 28TE with "The BEAST"
Sonny IV
2006 35TE Convertible, Volvo D6-370's
Former owner - Sonny III, 1997 28TE with "The BEAST"
-
- Gold Member
- Posts: 2115
- Joined: Fri Sep 22, 2006 7:35 am
- Home Port: Mystic, CT
- Location: New Port Richey, FL
Re: Gernerator installation
Should be located forward of the engine. 5.5 should be large enough to handle loads on a 36 ft boat without any issues.
Formerly
1983 40 Albin trunk cabin
Attitude Adjustment
Mystic, CT
1983 40 Albin trunk cabin
Attitude Adjustment
Mystic, CT
-
- Gold Member
- Posts: 23
- Joined: Mon Jul 18, 2011 11:16 am
- Home Port: Trident Yacht Club, Gananoque, Ontario, Canada
Re: Generator installation
On our 1980 Albin 36 DC s/n 258, a Westerbeke 4.0BCD (3-cylinder 0.808L 8.1 HP diesel engine running at 1800 RPM drives a 4.0KW (120VAC @ 60Hz) generator), produces a maximum of 33.3 Amps. The generator is transverse mounted ahead of the vessel’s main engine as shown on the attached photo.
You do not have the required permissions to view the files attached to this post. To view images, please register for a free account.
Robert Plante
1980 Albin 36 DC; FL120
1980 Albin 36 DC; FL120
-
- Gold Member
- Posts: 102
- Joined: Sat Apr 04, 2009 8:13 am
- Home Port: Avalon, NJ
Re: Gernerator installation
If you like camping then 5.5kw is enough...your panel if single 30 Amp cord.... is only set up for 3.5kw or so depending how you have things wired.
I find my 2 30's never enough sometimes (genset is 8kw) and plan on upgrading to 50 amp service wich is 2 50 amp panels...even then...between a hot water heater, some electric heat/air, microwave and another 110 volt appliance or 2 even overwhelms 2 30 amp cords/services (certainly the main panel). So if you don't mind using 1-3 thigs at a time and swapping cords, and waiting...then you'll be fine.
I find my 2 30's never enough sometimes (genset is 8kw) and plan on upgrading to 50 amp service wich is 2 50 amp panels...even then...between a hot water heater, some electric heat/air, microwave and another 110 volt appliance or 2 even overwhelms 2 30 amp cords/services (certainly the main panel). So if you don't mind using 1-3 thigs at a time and swapping cords, and waiting...then you'll be fine.
Scott Neeld
Albin 40 Trawler
Albin 40 Trawler
- Captn_Dwt
- Gold Member
- Posts: 70
- Joined: Tue Sep 20, 2011 9:45 am
- Home Port: Pleasant Cove, Boothbay, ME
- Location: Boothbay, Maine
Re: Gernerator installation
Hello!
My 1980 36 DC has a new Yanmar 5Kw installation. It's well done from my view. The unit is in-line with and just ahead of the main engine. There's room to work on all areas of the unit, and, it's presence does not stop access to any part of the engine room area. The only drawback "may" be that it covers access to the holding tank (which I've not been able to put a hand on yet...but I think it's below the flooring at that point.). Having lived with generators for many years, I can vouch that it's plenty of power unless you have many electric appliances AND electric stove/oven. Remember, any diesel want's to work hard, not loaf.
Best wishes
My 1980 36 DC has a new Yanmar 5Kw installation. It's well done from my view. The unit is in-line with and just ahead of the main engine. There's room to work on all areas of the unit, and, it's presence does not stop access to any part of the engine room area. The only drawback "may" be that it covers access to the holding tank (which I've not been able to put a hand on yet...but I think it's below the flooring at that point.). Having lived with generators for many years, I can vouch that it's plenty of power unless you have many electric appliances AND electric stove/oven. Remember, any diesel want's to work hard, not loaf.
Best wishes
- bccanucker
- Gold Member
- Posts: 179
- Joined: Mon Apr 05, 2010 8:52 pm
- Home Port: Gibsons Marina, BC, Canada
- Location: Sechelt, BC, Canada
Re: Gernerator installation
Jazzzman: A 5.5 should be fine. On our last boat which we had for 10 years we had a 5.0. Our main use was to charge batteries when down and to heat up the hot water when needed.
We now have a 36' aft Cabin. It used to have a genset but I have not for sure figured out where it was installed. Right in front (towards the bow) of the engine we have our house batteries and then a large space from there to the front of the engine room. I think it probably was there but i'm sure glad it isn't now as I love having that space to get into the front engine room.
Instaed of installing another genset we put on solar panels.
Capt_dwt: You are right that's where the holding tank is.
We now have a 36' aft Cabin. It used to have a genset but I have not for sure figured out where it was installed. Right in front (towards the bow) of the engine we have our house batteries and then a large space from there to the front of the engine room. I think it probably was there but i'm sure glad it isn't now as I love having that space to get into the front engine room.
Instaed of installing another genset we put on solar panels.
Capt_dwt: You are right that's where the holding tank is.
Roy Warner
Blue Heron
1988 36' Classic
Blue Heron